Note

Electrode should be stored in clean and dry place. When stocked in open area, it should be covered with rain-proof tarpaulin and the number of piling layers ought not to exceed four.
2020-08-28
Note

Graphite electrode should be covered with rain-proof tarpaulin in the process of transportation.
2020-08-28
Note

Be careful when transporting and pilling the electrodes with forklift and avoid collisions. One layer of goods at a time, notice the balance and alignment to avoid falling or breakage
2020-08-28
Note

Please clean the electrode threads first before connection, then screw the nipple into one end of the electrode. Don't touch the thread, and don't put the joint directly into the working electrode on furnace.
2020-08-28
Note

When loading and unloading with forklift, additional wire rope must be used and steel wrapping tape can not be employed directly to fetch electrode.
2020-08-28
Note

Electrodes should be dried next to electric furnace before using. The temperature should not exceed 120 °C and the time should not be less than 48 hours.
2020-08-28
Note

When using electrode, special tools should be employed to cut the steel wrapping tape, and crane should not be adopted to avoid bursting.
2020-08-28
Note

Use revolved resilient hanger and put soft cushions under the electrode nipple to avoid breakage of thread.
2020-08-28
Note

Before connecting, clean the screw thread of electrode with compressed air free of oil and water.
2020-08-28
Note

When connecting, the electrode is aligned with the center axis of the nipple to which is the connected.
2020-08-28
Note

Use special caliper to tight electrode according to rated torque by mechanical way, hydraulic pressure or wind pressure equipment should also be available.
2020-08-28
Note

Steel-wire ball, metallic brush or emery cloth is not allowed for cleaning electrode thread, but compressed air free of oil and water is available.
2020-08-28
Note

Clamp holder should be placed out of the alarm line. (Note: clamp holder should not clamp at alarm line zone, or the middle of the electrode, as it is easy to cause the rupture of the electrode) Clamp holder and interfaces of the electrode must be cleaned regularly to keep good touch with electrode.
2020-08-28
Note

To avoid the electrode breakage, insulating materials should not be put into the furnace. The working current of electrode must be conformity with the allowable current of electrode in the instructions.
2020-08-28
Note

In order to avoid electrode breakage, put the large materials in lower part and small materials on the upper part.